NESEDF2B console login: 2023/11/25-16:24:04, [FV-1001], 19266, CHASSIS, INFO, NESEDF2B, Flow Vision daemon initialized. SNMP Research EMANATE/Lite Agent Version 16.2.0.9 Copyright 1989-2006 SNMP Research, Inc. ki_state_set: redundant ACTIVATE for instance 1 2023/11/25-16:24:18, [ZONE-1022], 19267, FID 128, INFO, NESEDF2B, The effective configuration has changed to SNM_BCSI. 2023/11/25-16:24:18, [FV-1002], 19268, FID 128, INFO, NESEDF2B, Flow Vision Config Replay Completed Successfully. Nov 25 16:24:20All service instances on Active 2023/11/25-16:24:23, [EM-1034], 19269, CHASSIS, ERROR, Brocade6505, PS 2 set to faulty, rc=2000e. POST1: started running Sat Nov 25 16:24:23 JST 2023 POST1: Test #1 - Running Turboramtest 2023/11/25-16:24:24, [LOG-1000], 19273, CHASSIS, INFO, Brocade6505, Previous message repeated 4 time(s). 2023/11/25-16:24:26, [HIL-1610], 19274, CHASSIS, WARNING, Brocade6505, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on. POST1: Script PASSED with exit status of 0 Sat Nov 25 16:24:37 JST 2023 took (0:0:14) POST2: started running Sat Nov 25 16:24:40 JST 2023 POST2: Test #1 - Running portloopbacktest POST2: Script PASSED with exit status of 0 Sat Nov 25 16:25:09 JST 2023 took (0:0:29) 2023/11/25-16:25:10, [BL-1000], 19275, CHASSIS, INFO, Brocade6505, Initializing ports... 2023/11/25-16:25:10, [BL-1001], 19276, CHASSIS, INFO, Brocade6505, Port initialization completed. 2023/11/25-16:25:28, [TS-1001], 19277, FID 128, WARNING, NESEDF2B, NTP Query failed: 256. 2023/11/25-16:25:34, [FW-1010], 19278, FID 128, WARNING, NESEDF2B, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY). 2023/11/25-16:25:58, [FW-1424], 19279, FID 128, WARNING, NESEDF2B, Switch status changed from HEALTHY to MARGINAL. 2023/11/25-16:25:59, [FW-1427], 19280, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Power supply: 1 bad. 2023/11/25-16:25:59, [FW-1431], 19281, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Fan: 1 bad. 2023/11/25-16:26:50, [TS-1001], 19282, FID 128, WARNING, NESEDF2B, NTP Query failed: 256.
Brocade 6505 ファイバチャネルスイッチ 現状品
商品説明+++ 御覧いただきありがとうございます
1.メーカー、型番:
*Brocade 6505 ファイバチャネルスイッチ 現状品。
2.
*通電、コンソールまでの確認のみです。その他、
詳細なチェックは行なって おりませんので、
ノーサポート、ノークレーム、ノーリターンでお願いします。
*外装に擦り傷・塗装剥げ・シール痕などがございます。
*その他、写真を御覧ください。 ご了承の上、検討してください。
3.付属品:本体のみです。その他、なし。
4.コンソール結果下記です。
The system is coming up, please wait...
U-Boot 1.1.3 (Nov4 2015 - 11:09:27)
CPU:AMCC PowerPC 440EPx Rev. A at 660 MHz (PLB=132, OPB=66, EBC=33 MHz)
No Security/Kasumi support
I2C boot EEPROM enabled
Bootstrap Option G - Boot ROM Location I2C (Addr 0x54)
Internal PCI arbiter enabled, PCI async ext clock used
32 kB I-Cache 32 kB D-Cache
Board: Tomtoo
I2C:ready
DRAM:Initializing DDRSDRAM
DQS calibration - Window detected:
max_passing_cases = 52
wr_dqs_shift= 95
dll_dqs_delay_X= 28
dll_dqs_delay_X window = 3 - 54
DDR0_09=0x00011d5f
DDR0_22=0x03267f0b
DDR0_17=0x1c006000
DDR0_18=0x1c1c1c1c
DDR0_19=0x1c1c1c1c
Zeroing SDRAM...DONE
DDR: 1024 MB
POST RAM test disabled.
Now running in RAM - U-Boot at: 3fb26000
trap_init : 0x0
system inventory subsystem initialized
FLASH: Tomtoo CFI Flash Driver Initialized
4 MB
CPLD:
DEBUG: ASIC Reset Enable Register Offset:0x88 Value:0x03...
CPLD: Reseting Bridge & ASIC...
Init complete
PCI: gd->brcd_flags = 0, PCI init
Skip our host bridge
01001657001d02801a
000710b58112060418
In:serial
Out:serial
Err:serial
Net:
Checking system RAM - press any key to stop test
Checking memory address: 00100000
System RAM test using Default POST RAM Test succeeded.
set_bootstatus: BS_LOAD_OS, platform_idx = 16
Type run flash_nfs to mount root filesystem over NFS
Hit ESC to stop autoboot:0
Map file at LBA sector 0x1a7758
do_bootm 171: load_addr 0x00100000 addr 0x00400000
do_bootm 174: ## Booting image at 00400000 load_addr 0x00100000 ...
Image Name:Linux-2.6.14.2
Image Type:PowerPC Linux Multi-File Image (uncompressed)
Data Size:4290075 Bytes =4.1 MB
Load Address: 00000000
Entry Point:00000000
Contents:
Image 0:3211398 Bytes =3.1 MB
Image 1:1078663 Bytes =1 MB
do_bootm_linux 565: ## Current stack ends at 0x3FAE4BA8 => set upper limit to 0x00C00000
## initrd at 0x007100D4 ... 0x0081765A (len=1078663=0x107587)
Loading Ramdisk to 1fef8000, end 1ffff587 ... OK
initrd_start = 1fef8000, initrd_end = 1ffff587
## Transferring control to Linux (at address 00000000) ...
Start Autoneg
Installing Linux 2.6 Kernel
Attempting to find a root file system on hda2...
INIT: version 2.78 booting
Bypassing firmware validation.
INIT: Entering runlevel: 3
Starting Fabric OS Services...
FIPS off, RRD...
Found 2(threshold 5) abnormal reboots within 3000 seconds window(threshold)
sys_chip_init: class 0 max 24 Done
ethsw_ha_enabled = 1
uptime: 4293889121; sup_qid: 0
.
2023/11/25-16:23:53, [HAM-1004], 19265, CHASSIS, INFO, Brocade6505, Processor rebooted - Reset.
Fabric OS (NESEDF2B)
NESEDF2B console login: 2023/11/25-16:24:04, [FV-1001], 19266, CHASSIS, INFO, NESEDF2B, Flow Vision daemon initialized.
SNMP Research EMANATE/Lite Agent Version 16.2.0.9
Copyright 1989-2006 SNMP Research, Inc.
ki_state_set: redundant ACTIVATE for instance 1
2023/11/25-16:24:18, [ZONE-1022], 19267, FID 128, INFO, NESEDF2B, The effective configuration has changed to SNM_BCSI.
2023/11/25-16:24:18, [FV-1002], 19268, FID 128, INFO, NESEDF2B, Flow Vision Config Replay Completed Successfully.
Nov 25 16:24:20All service instances on Active
2023/11/25-16:24:23, [EM-1034], 19269, CHASSIS, ERROR, Brocade6505, PS 2 set to faulty, rc=2000e.
POST1: started running Sat Nov 25 16:24:23 JST 2023
POST1: Test #1 - Running Turboramtest
2023/11/25-16:24:24, [LOG-1000], 19273, CHASSIS, INFO, Brocade6505, Previous message repeated 4 time(s).
2023/11/25-16:24:26, [HIL-1610], 19274, CHASSIS, WARNING, Brocade6505, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on.
POST1: Script PASSED with exit status of 0 Sat Nov 25 16:24:37 JST 2023 took (0:0:14)
POST2: started running Sat Nov 25 16:24:40 JST 2023
POST2: Test #1 - Running portloopbacktest
POST2: Script PASSED with exit status of 0 Sat Nov 25 16:25:09 JST 2023 took (0:0:29)
2023/11/25-16:25:10, [BL-1000], 19275, CHASSIS, INFO, Brocade6505, Initializing ports...
2023/11/25-16:25:10, [BL-1001], 19276, CHASSIS, INFO, Brocade6505, Port initialization completed.
2023/11/25-16:25:28, [TS-1001], 19277, FID 128, WARNING, NESEDF2B, NTP Query failed: 256.
2023/11/25-16:25:34, [FW-1010], 19278, FID 128, WARNING, NESEDF2B, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/11/25-16:25:58, [FW-1424], 19279, FID 128, WARNING, NESEDF2B, Switch status changed from HEALTHY to MARGINAL.
2023/11/25-16:25:59, [FW-1427], 19280, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Power supply: 1 bad.
2023/11/25-16:25:59, [FW-1431], 19281, FID 128, WARNING, NESEDF2B, Switch status change contributing factor Fan: 1 bad.
2023/11/25-16:26:50, [TS-1001], 19282, FID 128, WARNING, NESEDF2B, NTP Query failed: 256.
Fabric OS (NESEDF2B)
NESEDF2B console login: 注意事項+++ *専門知識が不足のため、保証が対応しておりません。
ジャンク扱いで返品返金を対応しておりません。
*品となりますので外観は多少傷、汚れ、
使用感等ございますことご了承ください。
*送料は梱包材費など含みます。ご了承ください。
*写真で判断しご了承の上ご入札ください。
(テスト用品が付属されていません。ご注意してください)。
*キャンセルされる場合は落札金額の30%を頂戴いたします。
*入札の取り消しについて平日(月~金)09:00~17:00しか対応しておりません。
祝日,時間外に対応出来かねます。ご了承ください。
*追跡番号付いてない配送方法について
紛失、届かなかった場合は当方保証しておりません。
対応しておりません。ご了承ください。
*土曜・日曜・祝日は発送いたしません、
お急ぎの方はご遠慮ください。
*落札後7日経過しても連絡及び入金がない場合は
取り消しさせていただきます。
(その場合、自動的に「悪い」評価が付きます)。
*商品に関して質問がございましたら入札前質問提出してください。
落札後、ノークレーム、ノーリターンでお願いいたします。
ご理解の上、ご入札をお願い申し上げます。
*管理番号:A20720 送付方法+++ ゆうパック 支払方法+++ Yahoo!かんたん決済(詳細)
■ ゆうパック ■ 140サイズ 発送元:千葉県千葉県2,120円北海道2,680円青森県 秋田県 岩手県 宮城県 山形県 福島県2,170円茨城県 栃木県 群馬県 埼玉県 神奈川県 東京都 山梨県2,170円新潟県 長野県2,170円富山県 石川県 福井県2,170円静岡県 愛知県 三重県 岐阜県2,170円大阪府 京都府 滋賀県 奈良県 和歌山県 兵庫県2,300円岡山県 広島県 山口県 鳥取県 島根県2,440円香川県 德島県 愛媛県 高知県2,440円福岡県 佐賀県 長崎県 熊本県 大分県 宮崎県 鹿児島県2,680円沖縄県2,860円
この商品説明は オークション落札相場サイト「オークファン」出品テンプレート で作成されています。(ヤフオク専用)